ASHRAE Standard 90.1 User\'s Manual, 2016
- Standard 90.1 User's Manual [Go to Page]
- Contents
- 01 Purpose
- 02 Scope
- 03 Definitions, Abbreviations, and Acronyms
- 4 Administration and Enforcement [Go to Page]
- Scope and Compliance (4.1.1 and 4.2) [Go to Page]
- Administrative Requirements (4.1.2)
- Alternative Materials, Methods of Construction, or Design (4.1.3)
- Validity (4.1.4)
- Other Laws (4.1.5)
- Referenced Standards (4.1.6)
- Normative Appendices (4.1.7)
- Informative Appendices (4.1.8)
- Compliance Documentation (4.2.2)
- Labeling of Materials and Equipment (4.2.3)
- Inspections (4.2.4)
- Verification and Commissioning Reporting (4.2.5)
- 5 Building Envelope [Go to Page]
- General (5.1) [Go to Page]
- Scope (5.1.1)
- Space Conditioning Categories (5.1.2)
- Envelope Alterations (5.1.3)
- Climate (5.1.4)
- Compliance Paths (5.2)
- Mandatory Provisions (5.4) [Go to Page]
- Insulation (5.4.1)
- Fenestration and Doors (5.4.2)
- Air Leakage (5.4.3)
- Prescriptive Building Envelope Option (5.5) [Go to Page]
- Using the Criteria Tables (5.5.1 and 5.5.2)
- Opaque Areas (5.5.3)
- Fenestration (5.5.4)
- Building Envelope Trade-Off Option (5.6)
- Product Information and Installation Requirements (5.8) [Go to Page]
- Insulation (5.8.1)
- Fenestration and Doors (5.8.2)
- Inspection and Verification (5.9)
- 6 HVAC Systems [Go to Page]
- General (6.1) [Go to Page]
- Scope (6.1.1)
- Compliance Paths (6.2)
- Simplified Approach Option (6.3)
- Prescriptive Path (Section 6.5)
- Alternative Compliance Path (6.6)
- Energy Cost Budget Method (Section 11)
- Performance Rating Method (Appendix G)
- Simplified Approach Option for HVAC Systems (6.3) [Go to Page]
- Scope (6.3.1)
- Criteria (6.3.2)
- Mandatory Provisions (6.4) [Go to Page]
- Equipment Efficiencies, Verification, and Labeling Requirements (6.4.1)
- Calculations (6.4.2)
- Controls and Diagnostics (6.4.3)
- HVAC&R System Construction and Insulation (6.4.4)
- Walk-In Coolers and Walk-In Freezers (6.4.5)
- Refrigerated Display Case (6.4.6)
- Prescriptive Path (6.5) [Go to Page]
- Economizers (6.5.1)
- Simultaneous Heating and Cooling Limitation (6.5.2)
- Air System Design and Control (6.5.3)
- Hydronic System Design and Control (6.5.4)
- Heat-Rejection Equipment (6.5.5)
- Energy Recovery (6.5.6)
- Exhaust Systems (6.5.7)
- Radiant Heating Systems (6.5.8)
- Hot-Gas Bypass Limitation (6.5.9)
- Door Switches (6.5.10)
- Refrigeration Systems (6.5.11)
- Alternative Compliance Path (6.6) [Go to Page]
- Computer Room Systems (6.6.1)
- Submittals (6.7) [Go to Page]
- Completion Requirements (6.7.2) [Go to Page]
- Drawings (6.7.2.1)
- Manuals (6.7.2.2)
- System Balancing (6.7.2.3) [Go to Page]
- General (6.7.2.3.1)
- Air System Balancing (6.7.2.3.2)
- Hydronic System Balancing (6.7.2.3.3)
- System Commissioning (6.7.2.4)
- ( Minimum Equipment Efficiency Tables (6.8) [Go to Page]
- Table 6.8.1-1—Electrically Operated Unitary Air Conditioners and Condensing Units— Minimum Efficiency Requirements
- Table 6.8.1-2—Electrically Operated Unitary and Applied Heat Pumps— Minimum Efficiency Requirements
- Table 6.8.1-3— Water-Chilling Packages—Minimum Efficiency Requirements
- Table 6.8.1-4—Electrically Operated Packaged Terminal Air Conditioners, Packaged Terminal Heat Pumps, Single-Package Vertical Air Conditioners, Single-Package Vertical Heat Pumps, Room Air Conditioners, and Room Air-Conditioner Heat Pumps— Minimum Eff...
- Table 6.8.1-5—Warm-Air Furnaces and Combination Warm-Air Furnaces/Air-Conditioning Units, Warm-Air Duct Furnaces, and Unit Heaters—Minimum Efficiency Requirements
- Table 6.8.1-6—Gas- and Oil-Fired Boilers—Minimum Efficiency Requirements
- Table 6.8.1-7—Performance Requirements for Heat-Rejection Equipment—Minimum Efficiency Requirements
- Table 6.8.1-8—Heat Transfer Equipment—Minimum Efficiency Requirements
- Table 6.8.1-9—Electrically Operated Variable-Refrigerant-Flow Air Conditioners—Minimum Efficiency Requirements
- Table 6.8.1-10—Electrically Operated Variable-Refrigerant-Flow Air-to-Air and Applied Heat Pumps—Minimum Efficiency Requirements
- Table 6.8.1-11—Air Conditioners and Condensing Units Serving Computer Rooms—Minimum Efficiency Requirements
- Table 6.8.1-12—Commercial Refrigerators and Freezers—Minimum Efficiency Requirements
- Table 6.8.1-13—Commercial Refrigeration—Minimum Efficiency Requirements
- Table 6.8.1-14—Vapor Compression Based Indoor Pool Dehumidifiers—Minimum Efficiency Requirements
- 7 Service Water Heating [Go to Page]
- General (7.1) [Go to Page]
- Scope (7.1.1)
- Compliance Paths (7.2)
- Mandatory Provisions (7.4) [Go to Page]
- Load Calculations (7.4.1)
- Equipment Efficiency (7.4.2)
- ( Service Hot-Water Piping Insulation (7.4.3)
- Service Water Heating System Controls (7.4.4)
- Swimming Pools (7.4.5)
- Heat Traps (7.4.6)
- Prescriptive Path (7.5) [Go to Page]
- Space Heating and Service Water Heating (7.5.1)
- Service Water Heating Equipment (7.5.2)
- Buildings with High-Capacity Service Water Heating Systems (7.5.3)
- 8 Power [Go to Page]
- General (8.1) [Go to Page]
- Scope (8.1.1)
- Mandatory Provisions (8.4) [Go to Page]
- Voltage Drop (8.4.1)
- Automatic Receptacle Control (8.4.2)
- Electrical Energy Monitoring (8.4.3)
- Low-Voltage Dry-Type Distribution Transformers (8.4.4)
- Submittals (8.7) [Go to Page]
- Drawings (8.7.1)
- Manuals (8.7.2)
- 9 Lighting [Go to Page]
- General (9.1) [Go to Page]
- Scope (9.1.1)
- Lighting Alterations (9.1.2)
- Installed Lighting Power (9.1.3)
- Interior and Exterior Luminaire Wattage (9.1.4)
- Compliance (9.2) [Go to Page]
- Prescriptive Requirements (9.2.2)
- Mandatory Provisions (9.4) [Go to Page]
- Lighting Control (9.4.1)
- Functional Testing (9.4.3)
- Building Area Method Compliance Path (9.5)
- Alternative Compliance Path: Space-by-Space Method (9.6) [Go to Page]
- Additional Interior Lighting Power (9.6.2)
- Additional Interior Lighting Power Using Nonmandatory Controls (9.6.3)
- Room Geometry Adjustment (9.6.4)
- Submittals (9.7) [Go to Page]
- General (9.7.1)
- Completion Requirements (9.7.2)
- 10 Other Equipment [Go to Page]
- General (10.1) [Go to Page]
- Scope (10.1.1)
- Mandatory Provisions (10.4) [Go to Page]
- Electric Motors (10.4.1)
- Service Water Pressure-Booster Systems (10.4.2)
- Elevators (10.4.3)
- Escalators and Moving Walks (10.4.4)
- 11 Energy Cost Budget Method [Go to Page]
- General (11.1) [Go to Page]
- Scope and Limitations (11.1.1, 11.1.2, and 11.1.3)
- Compliance (11.2)
- Simulation General Requirements (11.4) [Go to Page]
- Simulation Program (11.4.1)
- Climatic Data (11.4.2)
- Renewable, Recovered, and Purchased Energy (11.4.3)
- Compliance Calculations (11.4.4)
- Exceptional Calculation Methods (11.4.5)
- Calculation of Design Energy Cost and Energy Cost Budget (11.5)
- Documentation Requirements (11.7)
- G Performance Rating Method [Go to Page]
- General (G1) [Go to Page]
- Performance Rating Method Scope (G1.1)
- Performance Rating (G1.2)
- Documentation Requirements (G1.3)
- Simulation General Requirements (G2) [Go to Page]
- Performance Calculations (G2.1)
- Simulation Program (G2.2)
- Minimum Modeling Capabilities (G2.2.1)
- Proposed Building and Baseline Building Performance (G2.2.2)
- Design Load Calculations (G2.2.3)
- Testing (G2.2.4)
- Climatic Data (G2.3)
- Renewable, Recovered, and Purchased Energy (G2.4)
- Exceptional Calculation Methods (G2.5)
- Calculation of the Proposed Design and Baseline Building Performance (G3) [Go to Page]
- Building Performance Calculations (G3.1)
- General Baseline HVAC System Requirements (G3.1.2)
- System-Specific Baseline HVAC System Requirements (G3.1.3)