Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN 15269-2:2024 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Fire resistance of hinged and pivoted steel doorsets, 2025
- undefined
- European foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- Figure 2 — Faces and sides of a door leaf
- 4 Determination of the field of extended application [Go to Page]
- 4.1 General
- 4.2 How to use extended application rules in Annex A
- 4.3 Procedure for maximum field of extended application
- 4.4 Analysis of test results
- 5 Extended application report
- 6 Classification report
- Annex A (normative) Construction parameter variations
- A.1 General
- A.2 Guideline for the evaluation of the required orientation of the test specimens (only for doorsets that are required to be tested from both directions)
- Table A.1 — Construction parameter variations — Section A — Door leaf
- Table A.2 — Construction parameter variations — Section B — Door frame
- Table A.3 — Construction parameter variations — Section C — Items of building hardware
- Table A.4 — Construction parameter variations — Section D — Support/attachment — door leaf to framing
- Table A.5 — Construction parameter variations — Section E — Side/transom panels and flush overpanels
- Table A.6 — Construction parameter variations — Section F — Glazing for door leaf/leaves or side/transom and flush overpanels
- Table A.7 — Construction parameter variations — Section G — Supporting construction and attachment (technique) of door frame or side/transom panels/flush overpanels
- Table A.1.19 — Latched condition for single and double leaf doorsets
- Table B.2.6 — Possible frame infill materials
- Table C.8.4 — Alternative fitting positions of Face fixed door closers / power operated opening devices
- Table F.1.3 — Glazing — Transposition between leaves
- Table F.1.4 — Glazing — Size variation between smallest and largest tested glazing
- Figure A.1 — Number of leaves
- Figure A.2 — Number of vertical panels per leaf
- Figure A.3 — Intumescent seals between frame and door leaf/leaves — Location towards the frame rebate
- Figure A.4 — Intumescent seals between frame and door leaf/leaves — Location away from the frame rebate
- Figure A.5 — Non-intumescent seals between frame and door leaf/leaves — Reaction to fire class A1, (fitted in leaf or frame) — Location
- Figure A.6 — Non-intumescent seals between frame and door leaf/leaves — < Reaction to fire class A1, (fitted in leaf or frame) — Location
- Figure A.7 — Non-intumescent seals between frame and door leaf/leaves — Reaction to fire class A1, (fitted in leaf or frame) — Add
- Figure A.8 — Non-intumescent seals between frame and door leaf/leaves — Reaction to fire class A1, (fitted in leaf or frame) — Remove
- Figure A.9 — Non-intumescent seals between frame and door leaf/leaves — < Reaction to fire class A1, (fitted in leaf or frame) — Add
- Figure A.10 — Non intumescent seals between frame and door leaf / leaves — < Reaction to fire class A1, (fitted in leaf or frame) — Remove
- Figure A.11 — Air transfer grilles (ventilation grilles/louvres)
- Figure A.12 — Air transfer grilles (ventilation grilles/louvres) — Change location in horizontal direction
- Figure A.13 — Air transfer grilles (ventilation grilles/louvres)
- Figure A.14 — Rebate — Add
- Figure A.15 — Rebate (door leaves to frames) — Remove
- Figure A.16 — Thickness of core material — Increase
- Figure A.17 — Thickness of core material — Decrease
- Figure A.18 — Pattern of core material - Increase number of pieces (two examples shown)
- Figure A.19 — Pattern of core material — Decrease number of pieces
- Figure A.20— Number of layers of identical and/or different materials — Increase
- Figure A.21 — Number of layers of identical and/or different materials — Decrease
- Figure A.22 — Metal armour sheet (internally mounted)
- Figure A.23 — Electronic security mesh
- Figure A.24 — Cross-section dimension of stiffening elements
- Figure A.25 — Number of intermediate stiffening elements
- Figure A.26 — Stiffening elements — Location
- Figure A.27 — Number of stiffening element fixing points
- Figure A.28 — Overlap dimension of leaf/panel edge rebate
- Figure A.29 — Overlap dimension of leaf/panel edge rebate
- Figure A.30 — Additional overlapping edge at the bottom of the door leaf
- Figure A.31 — Leaf edge detail — Shape
- Figure A.32 — Jointing/assembly technique – Alternative (welding/riveting/screwing)
- Figure A.33 — Dimension of intumescent seals (leaf or frame fitted)
- Figure A.34 — Dimension of non-intumescent seals (Reaction to fire class A1) — leaf or frame fitted
- Figure A.35 — Dimension of non-intumescent seals (
- Figure A.36 — Decorative laminates and timber veneers on the face (on leaf or frame) — Add
- Figure A.37 — Decorative laminates and timber veneers on the face (on leaf or frame) — Remove
- Figure A.38 — Decorative laminates and timber veneers on the edges (on leaf or frame) — Add
- Figure A.39 — Decorative laminates and timber veneers on the edges (on leaf or frame) — Remove
- Figure A.40 — Protective elements (e.g. push plates, kick plates and bumpers) — Face fixed — Add
- Figure A.41 — Mouldings/profiles — Add/Remove
- Figure A.42 — Height of hatch door frame above floor — Variation
- Figure A.43 — Overall dimensions and shape — Increase
- Figure A.44 — Overall dimensions and shape — Decrease
- Figure A.45 — Thickness of metal
- Figure A.46 — Number of latches/locks/strike plates — Increase
- Figure A.47 — Number of latches/locks/strike plates — Decrease
- Figure A.48 — Vertical position of single latch/lock
- Figure A.49 — Vertical position of multiple latches/locks (with or without connecting rods)
- Figure A.50 — Latches/locks — Alternative type
- Figure A.53 — Bolts (flush, internal and surface mounted) — Add
- Figure A.54 — Number of hinges or spring hinges/dog bolts
- Figure A.55 —Hinges — Alternative type
- Figure A.56 — Dog bolts — Alternative type
- Figure A.59 — Distances between top and bottom hinges and intermediate dog bolts / movement restrictors — Increase/Decrease
- Figure A.60 — Face fixed door closers / Power operated opening devices (drives)— Alternative fitting positions
- Figure A.61 — Concealed head and bottom mounted door closers — Alternative type (change concealed for face mounted)
- Figure A.62 — Face fixed door closers — Alternative type (change face mounted for concealed)
- Figure A.63 — Cables and related accessories (e.g. cable transfer devices, cable loops, protective conduits) - fitted in or on the door leaf or frame — Add
- Figure A.64 — Door viewer (spy hole) - mechanical or electronic/key tubes (access port within doorset for key retrieval) - mortised/concealed — Add
- Figure A.65 — Size (area, width, height)— Increase
- Figure A.66 — Thickness of glass
- Figure A.67 — Dimensions of each glazing — Increase
- Figure A.68 — Dimensions in each glazing — Decrease
- Figure A.69 — Decorative capping, edge cover — Add or exchange
- Figure A.70 — Number of glazed apertures — Increase
- Figure A.71 — Number of glazed apertures — Decrease
- Figure A.74 — Distance between glazed apertures — Decrease
- Figure A.75 — Fixing to floor
- Figure A.78 — Standard flexible supporting construction — Strengthening
- Figure A.79 — Overlap (rebate / astragal) between door leaves and frame or between meeting edges — Decrease overlap thickness
- Figure A.80 — Overlap (rebate / astragal) between door leaves and frame or between meeting edges — Increase overlap thickness
- Figure A.81 — Door closers
- Figure A.82 — Single and double acting
- Figure A.83 — Face mounted finger protection device — Add / Remove
- Figure A.84 — Edge mounted finger protection device — Add / Remove
- Figure A.85 — Internally mounted reinforcement for face fixed components — Change location
- Figure A.86 — Sealant between door frame and supporting construction — Add
- Figure A.87 — Sealant between door frame and supporting construction — Remove
- Annex B (normative) Arrangements for doorsets incorporating side and/or overpanels
- Table B.1 — Permissible variations for panel arrangements with transom panels
- Table B.2 — Permissible variations for panel arrangements with flush overpanels
- Figure B.2 — Side/flush overpanel arrangement
- Bibliography [Go to Page]