PD CEN/TS 16516:2013 Construction products. Assessment of release of dangerous substances. Determination of emissions into indoor air, 2013
- 64_e_stf.pdf [Go to Page]
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviations [Go to Page]
- 3.1 Terms relating to sampling and products
- 3.2 Terms relating to emissions into indoor air and associated laboratory testing
- 3.3 Terms relating to determination of emitted substances
- 3.4 Abbreviations
- 4 Intended conditions of use, emission scenarios and European reference room [Go to Page]
- 4.1 Intended conditions of use and emission scenario
- 4.2 Reference room and emission scenario [Go to Page]
- 4.2.1 General
- 4.2.2 Dimensions and loading factors in the reference room
- 4.2.3 Ventilation in the reference room
- 4.2.4 Climate conditions in the reference room
- 4.3 Time schedule of emission(s) determination
- 5 Product sampling and transport to the laboratory [Go to Page]
- 5.1 Introduction
- 5.2 Objective of sampling
- 5.3 Preparation of a sampling plan and sampling strategy [Go to Page]
- 5.3.1 General
- 5.3.2 Sampling approach
- 5.3.3 Population and sub-population
- 5.3.4 Scale
- 5.3.5 Size of samples, of increments when relevant, and sampling techniques
- 5.3.6 Sampling of complex, composite and large products
- 5.3.7 Sampling location and moment
- 5.4 Information from the testing laboratory needed to complement the product sampling plan
- 5.5 Packaging and transport of laboratory sample
- 5.6 Sample description, marking of laboratory sample and sampling report
- 5.7 Chain of custody report
- 5.8 Dispatch of product samples, time schedule
- 6 Handling of product samples in the laboratory [Go to Page]
- 6.1 Storage of sample in the testing laboratory
- 6.2 Preparation of the test specimen
- 7 Test chamber conditions [Go to Page]
- 7.1 Principles
- 7.2 Dimensions of test specimen
- 7.3 Loading factor
- 7.4 Ventilation
- 7.5 Air velocity
- 7.6 Cleanliness of test chamber
- 7.7 Testing climate (temperature, relative humidity of supply air)
- 7.8 Storage of test specimen
- 7.9 Large bulk products
- 7.10 Volume of test chamber
- 7.11 Placement of test specimen in test chamber
- 8 Determination of volatile organic compounds in test chamber air [Go to Page]
- 8.1 Common requirements
- 8.2 Determination of VOCs and SVOCs in test chamber air [Go to Page]
- 8.2.1 Introduction
- 8.2.2 Capillary GC column
- 8.2.3 Tube conditioning and laboratory blank tubes
- 8.2.4 Checking the test chamber blank
- 8.2.5 Sampling test chamber air
- 8.2.6 Calibration and analysis [Go to Page]
- 8.2.6.1 Reporting limit, quantification limit
- 8.2.6.2 Identified compounds (target and non-target compounds)
- 8.2.6.3 Unidentified compounds
- 8.2.7 Total volatile organic compounds (TVOC) and total semi-volatile organic compounds (TSVOC)
- 8.2.8 Quality control – Additional method performance checks required
- 8.3 Determination of formaldehyde and some other volatile carbonyl compounds in test chamber air
- 8.4 Quality control – External references
- 9 Calculation of specific emission rates and expression of results at the reference room
- 10 Reporting for the horizontal reference method [Go to Page]
- 10.1 General
- 10.2 Sampling
- 10.3 Handling of samples in the laboratory, preparation of test specimen
- 10.4 Test chamber conditions
- 10.5 Determination of vapour-phase organic compounds in test chamber air
- 10.6 Calculation and reporting of test results
- 11 Indirect methods
- Annex A (informative) Repeatability
- Annex B (informative) Examples of indirect methods (also called simplified, screening, secondary, derived or alternative methods) [Go to Page]
- B.1 General
- B.2 Indirect methods relative to testing devices for generating emissions [Go to Page]
- B.2.1 Emission cell
- B.2.2 Micro-chamber
- B.2.3 Thermal extraction
- B.3 Indirect methods relative to analysis [Go to Page]
- B.3.1 Headspace and in-can VOC determination
- B.3.2 VOC content determination
- B.3.3 Formaldehyde specific methods
- B.4 Indirect methods relative to the evaluation of the test result [Go to Page]
- B.4.1 Method integrated in production monitoring
- B.4.2 Prediction of results at 28 days
- Annex C (informative) Information on very volatile organic compound (VVOC) testing
- Annex D (informative) Key concepts for product sampling [Go to Page]
- D.1 Representativeness
- D.2 Uncertainty
- D.3 Aspects of repetitive sampling
- D.4 Series of steps in sampling
- D.5 Objective of sampling
- D.6 Preparation of a sampling plan
- D.7 Sampling strategy [Go to Page]
- D.7.1 General
- D.7.2 Sampling approach
- D.7.3 Population and sub-population
- D.7.4 Scale
- D.7.5 Size of increments and samples
- D.7.6 Sampling of complex, composite and large products
- D.7.7 Sampling location and moment
- Annex E (informative) Example of a form for the sampling report
- Annex F (informative) Example form for a chain of custody report
- Annex G (informative) Benzene artefact generation on Tenax
- Annex H (informative) Information on regulations concerning the emission into indoor air of dangerous substances from construction products [Go to Page]