ASHRAE/ICC 700-2015 National Green Building Standard, 2015
- Cover
- Copyright
- PREFACE
- 2015 Consensus Committee on theNational Green Building Standard™
- TABLE OF CONTENTS
- CHAPTER 1 SCOPE AND ADMINISTRATION [Go to Page]
- 101 GENERAL [Go to Page]
- 101.1 Title
- 101.2 Scope
- 101.3 Intent
- 101.4 Referenced documents
- 101.5 Appendices
- 102 CONFORMANCE [Go to Page]
- 102.1 Mandatory practices
- 102.2 Conformance language
- 102.3 Documentation
- 102.4 Alternative compliance methods
- 103 ADMINISTRATION [Go to Page]
- 103.1 Administration
- CHAPTER 2 DEFINITIONS [Go to Page]
- 201 GENERAL [Go to Page]
- 201.1 Scope
- 201.2 Interchangeability
- 201.3 Terms defined in other documents
- 201.4 Terms not defined
- 202 DEFINITIONS
- CHAPTER 3 COMPLIANCE METHOD [Go to Page]
- 301 GENERAL [Go to Page]
- 301.1 Environmental rating levels
- 301.2 Awarding of points
- 302 GREEN SUBDIVISIONS [Go to Page]
- 302.1 Site design and development
- 303 GREEN BUILDINGS [Go to Page]
- 303.1 Green buildings
- 304 GREEN MULTIFAMILY BUILDINGS [Go to Page]
- 304.1 Multifamily buildings
- 305 GREEN REMODELING [Go to Page]
- 305.1 Compliance
- 305.2 Compliance options
- 305.3 Whole-building rating criteria
- 305.4 Criteria for remodeled functional areas of buildings
- 306 GREEN ACCESSORY STRUCTURES [Go to Page]
- 306.1 Applicability
- 306.2 Compliance
- CHAPTER 4 SITE DESIGN AND DEVELOPMENT
- 400 SITE DESIGN AND DEVELOPMENT [Go to Page]
- 400.0 Intent
- 401 SITE SELECTION [Go to Page]
- 401.0 Intent
- 401.1 Infill site
- 401.2 Greyfield site
- 401.3 Brownfield site
- 402 PROJECT TEAM, MISSION STATEMENT, AND GOALS [Go to Page]
- 402.0 Intent
- 402.1 Team
- 402.2 Training
- 402.3 Project checklist
- 402.4 Development agreements
- 403 SITE DESIGN [Go to Page]
- 403.0 Intent
- 403.1 Natural resources
- 403.2 Building orientation
- 403.3 Slope disturbance
- 403.4 Soil disturbance and erosion
- 403.5 Stormwater management
- 403.6 Landscape plan
- 403.7 Wildlife habitat
- 403.8 Operation and maintenance plan
- 403.9 Existing buildings
- 403.10 Existing and recycled materials
- 403.11 Demolition of existing building
- 403.12 Environmentally sensitive areas
- 404 SITE DEVELOPMENT AND CONSTRUCTION [Go to Page]
- 404.0 Intent
- 404.1 On-site supervision and coordination
- 404.2 Trees and vegetation
- 404.3 Soil disturbance and erosion
- 404.4 Wildlife habitat
- 405 INNOVATIVE PRACTICES [Go to Page]
- 405.0 Intent
- 405.1 Driveways and parking areas
- 405.2 Street widths
- 405.3 Cluster development
- 405.4 Planning
- 405.5 Wetlands
- 405.6 Multi-modal transportation
- 405.7 Density
- 405.8 Mixed-use development
- 405.9 Open space
- 405.10 Community garden(s
- CHAPTER 5 LOT DESIGN, PREPARATION, AND DEVELOPMENT
- 500 LOT DESIGN, PREPARATION, AND DEVELOPMENT [Go to Page]
- 500.0 Intent
- 501 LOT SELECTION [Go to Page]
- 501.1 Lot
- 501.2 Multi-modal transportation
- 502 PROJECT TEAM, MISSION STATEMENT, AND GOALS [Go to Page]
- 502.1 Project team, mission statement, and goals
- 503 LOT DESIGN [Go to Page]
- 503.0 Intent
- 503.1 Natural resources
- 503.2 Slope disturbance
- 503.3 Soil disturbance and erosion
- 503.4 Stormwater management
- 503.5 Landscape plan
- 503.6 Wildlife habitat
- 503.7 Environmentally sensitive areas
- 503.8 Demolition of existing building
- 504 LOT CONSTRUCTION [Go to Page]
- 504.0 Intent
- 504.1 On-site supervision and coordination
- 504.2 Trees and vegetation
- 504.3 Soil disturbance and erosion implementation
- 505 INNOVATIVE PRACTICES [Go to Page]
- 505.0 Intent
- 505.1 Driveways and parking areas
- 505.2 Heat island mitigation
- 505.3 Density
- 505.4 Mixed-use development
- 505.5 Community garden(s
- 505.6 Multi-unit plug-in electric vehicle charging
- CHAPTER 6 RESOURCE EFFICIENCY [Go to Page]
- 601 QUALITY OF CONSTRUCTION MATERIALS AND WASTE [Go to Page]
- 601.0 Intent
- 601.1 Conditioned floor area
- 601.2 Material usage
- 601.3 Building dimensions and layouts
- 601.4 Framing and structural plans
- 601.5 Prefabricated components
- 601.6 Stacked stories
- 601.7 Prefinished materials
- 601.8 Foundations
- 601.9 Above grade wall systems
- 602 ENHANCED DURABILITY AND REDUCED MAINTENANCE [Go to Page]
- 602.0 Intent
- 602.1 Moisture management – building envelope
- 602.2 Roof surfaces
- 602.3 Roof water discharge
- 602.4 Finished grade
- 603 REUSED OR SALVAGED MATERIALS [Go to Page]
- 603.0 Intent
- 603.1 Reuse of existing building
- 603.2 Salvaged materials
- 603.3 Scrap materials
- 604 RECYCLED-CONTENT BUILDING MATERIALS [Go to Page]
- 604.1 Recycled content
- 605 RECYCLED CONSTRUCTION WASTE [Go to Page]
- 605.0 Intent
- 605.1 Construction waste management plan
- 605.2 On-site recycling
- 605.3 Recycled construction materials
- 606 RENEWABLE MATERIALS [Go to Page]
- 606.0 Intent
- 606.1 Biobased products
- 606.2 Wood-based products
- 606.3 Manufacturing energy
- 607 RECYCLING AND WASTE REDUCTION [Go to Page]
- 607.1 Recycling and composting
- 607.2 Food waste disposers
- 608 RESOURCE-EFFICIENT MATERIALS [Go to Page]
- 608.1 Resource-efficient materials
- 609 REGIONAL MATERIALS
- 609.1 Regional materials
- 610 LIFE CYCLE ASSESSMENT [Go to Page]
- 610.1 Life cycle assessment
- 611 INNOVATIVE PRACTICES [Go to Page]
- 611.1 Manufacturer’s environmental management system concepts
- 611.2 Sustainable products
- 611.3 Universal design elements
- 611.4 Product declarations
- CHAPTER 7 ENERGY EFFICIENCY [Go to Page]
- 701 MINIMUM ENERGY EFFICIENCY REQUIREMENTS [Go to Page]
- 701.1 Mandatory requirements
- 701.1.1 Minimum Performance Path requirements
- 701.1.2 Minimum Prescriptive Path requirements
- 701.1.3 HERS Index Target Path requirements
- 701.1.4 Alternative bronze level compliance
- 701.2 Emerald level points
- 701.3 Adopting entity review
- 701.4 Mandatory practices
- 701.4.1 HVAC systems
- 701.4.2 Duct systems
- 701.4.3 Insulation and air sealing
- 701.4.4 High-efficacy lighting
- 701.4.5 Boiler supply piping
- 702 PERFORMANCE PATH [Go to Page]
- 702.1 Point allocation
- 702.2 Energy performance levels
- 703 PRESCRIPTIVE PATH [Go to Page]
- 703.1 Mandatory practices
- 703.2 Building envelope
- 703.3 HVAC equipment efficiency
- 703.4 Duct systems
- 703.5 Water heating system
- 703.6 Lighting and appliances
- 703.7 Passive solar design
- 704 HERS INDEX TARGET PATH [Go to Page]
- 704.1 HERS index target compliance
- 704.2 Point calculation
- 705 ADDITIONAL PRACTICES [Go to Page]
- 705.1 Application of additional practice points
- 705.2 Lighting
- 705.3 Induction cooktop
- 705.4 Return ducts and transfer grilles
- 705.5 HVAC design and installation
- 705.6 Installation and performance verification
- 705.7 Submetering system
- 706 INNOVATIVE PRACTICES [Go to Page]
- 706.1 Energy consumption control
- 706.2 Renewable energy service plan
- 706.3 Smart appliances and systems
- 706.4 Pumps
- 706.5 On-site renewable energy system
- 706.6 Parking garage efficiency
- 706.7 Grid-interactive electric thermal storage system
- 706.8 Electrical vehicle charging station
- 706.9 Automatic demand response
- CHAPTER 8 WATER EFFICIENCY [Go to Page]
- 801 INDOOR AND OUTDOOR WATER USE [Go to Page]
- 801.0 Intent
- 801.1 Indoor hot water usage
- 801.2 Water-conserving appliances
- 801.3 Showerheads
- 801.4 Lavatory faucets
- 801.5 Water closets and urinals
- 801.6 Irrigation systems
- 801.7 Rainwater collection and distribution
- 801.8 Sediment filters
- 802 INNOVATIVE PRACTICES [Go to Page]
- 802.1 Reclaimed, gray, or recycled water
- 802.2 Reclaimed water, graywater, or rainwater pre-piping
- 802.3 Automatic shutoff water devices
- 802.4 Engineered biological system or intensive bioremediation system
- 802.5 Recirculating humidifier
- 802.6 Advanced wastewater treatment system
- CHAPTER 9 INDOOR ENVIRONMENTAL QUALITY [Go to Page]
- 901 POLLUTANT SOURCE CONTROL [Go to Page]
- 901.0 Intent
- 901.1 Space and water heating options
- 901.2 Solid fuel-burning appliances
- 901.3 Garages
- 901.4 Wood materials
- 901.5 Cabinets
- 901.6 Carpets
- 901.7 Floor materials
- 901.8 Wall coverings
- 901.9 Interior architectural coatings
- 901.10 Interior adhesives and sealants
- 901.11 Insulation
- 901.12 Carbon monoxide (CO) alarms
- 901.13 Building entrance pollutants control
- 901.14 Non-smoking areas
- 902 POLLUTANT CONTROL [Go to Page]
- 902.0 Intent
- 902.1 Spot ventilation
- 902.2 Building ventilation systems
- 902.3 Radon control
- 902.4 HVAC system protection
- 902.5 Central vacuum systems
- 902.6 Living space contaminants
- 903 MOISTURE MANAGEMENT: VAPOR, RAINWATER, PLUMBING, HVAC [Go to Page]
- 903.0 Intent
- 903.1 Plumbing
- 903.2 Duct insulation
- 903.3 Relative humidity
- 904 INDOOR AIR QUALITY [Go to Page]
- 904.0 Intent
- 904.1 Indoor Air Quality (IAQ) during construction
- 904.2 Indoor Air Quality (IAQ) post completion
- 905 INNOVATIVE PRACTICES [Go to Page]
- 905.1 Humidity monitoring system
- 905.2 Kitchen exhaust
- CHAPTER 10 OPERATION, MAINTENANCE, AND BUILDING OWNER EDUCATION [Go to Page]
- 1001 HOMEOWNER’S MANUAL AND TRAINING GUIDELINES FOR ONE- AND TWO-FAMILY DWELLINGS
- 1001.0 Intent
- 1001.1 Homeowner’s manual
- 1001.2 Training of initial homeowners
- 1002 CONSTRUCTION, OPERATION, AND MAINTENANCE MANUALS AND TRAINING FOR MULTIFAMILY
BUILDINGS [Go to Page]
- 1002.0 Intent
- 1002.1 Building construction manual
- 1002.2 Operations manual
- 1002.3 Maintenance manual
- 1002.4 Training of building owners
- 1003 PUBLIC EDUCATION [Go to Page]
- 1003.0 Intent
- 1003.1 Public education
- 1004 POST OCCUPANCY PERFORMANCE ASSESSMENT [Go to Page]
- 1004.0 Intent
- 1004.1 Verification system
- 1005 INNOVATIVE PRACTICES [Go to Page]
- 1005.1 (Reserved
- CHAPTER 11 REMODELING [Go to Page]
- 11.500 LOT DESIGN, PREPARATION, AND DEVELOPMENT [Go to Page]
- 11.500.0 Intent
- 11.501 LOT SELECTION [Go to Page]
- 11.501.2 Multi-modal transportation
- 11.502 PROJECT TEAM, MISSION STATEMENT, AND GOALS [Go to Page]
- 11.502.1 Project team, mission statement, and goals
- 11.503 LOT DESIGN [Go to Page]
- 11.503.0 Intent
- 11.503.1 Natural resources
- 11.503.2 Slope disturbance
- 11.503.3 Soil disturbance and erosion
- 11.503.4 Stormwater Management
- 11.503.5 Landscape plan
- 11.503.6 Wildlife habitat
- 11.503.7 Environmentally sensitive areas
- 11.504 LOT CONSTRUCTION [Go to Page]
- 11.504.0 Intent
- 11.504.1 On-site supervision and coordination
- 11.504.2 Trees and vegetation
- 11.504.3 Soil disturbance and erosion implementation
- 11.505 INNOVATIVE PRACTICES [Go to Page]
- 11.505.0 Intent
- 11.505.1 Driveways and parking areas
- 11.505.2 Heat island mitigation
- 11.505.3 Density
- 11.505.4 Mixed-use development
- 11.505.5 Community Garden(s
- 11.505.6 Multi-unit plug-in electric vehicle charging
- 11.601 QUALITY OF CONSTRUCTION MATERIALS AND WASTE [Go to Page]
- 11.601.0 Intent
- 11.601.1 Conditioned floor area
- 11.601.2 Material usage
- 11.601.3 Building dimensions and layouts
- 11.601.4 Framing and structural plans
- 11.601.5 Prefabricated components
- 11.601.6 Stacked stories
- 11.601.7 Prefinished materials
- 11.601.8 Foundations
- 11.602 ENHANCED DURABILITY AND REDUCED MAINTENANCE [Go to Page]
- 11.602.0 Intent
- 11.602.1 Moisture management – building envelope
- 11.602.2 Roof surfaces
- 11.602.3 Roof water discharge
- 11.602.4 Finished grade
- 11.603 REUSED OR SALVAGED MATERIALS [Go to Page]
- 11.603.0 Intent
- 11.603.1 Reuse of existing building
- 11.603.2 Salvaged materials
- 11.603.3 Scrap materials
- 11.604 RECYCLED-CONTENT BUILDING MATERIALS [Go to Page]
- 11.604.1 Recycled content
- 11.605 RECYCLED CONSTRUCTION WASTE [Go to Page]
- 11.605.0 Intent
- 11.605.1 Hazardous waste
- 11.605.2 Construction waste management plan
- 11.605.3 On-site recycling
- 11.605.4 Recycled construction materials
- 11.606 RENEWABLE MATERIALS [Go to Page]
- 11.606.0 Intent
- 11.606.1 Biobased products
- 11.606.2 Wood-based products
- 11.606.3 Manufacturing energy
- 11.607 RECYCLING AND WASTE REDUCTION [Go to Page]
- 11.607.1 Recycling and composting
- 11.607.2 Food waste disposers
- 11.608 RESOURCE-EFFICIENT MATERIALS [Go to Page]
- 11.608.1 Resource-efficient materials
- 11.609 REGIONAL MATERIALS [Go to Page]
- 11.609.1 Regional materials
- 11.610 LIFE CYCLE ASSESSMENT [Go to Page]
- 11.610.1 Life cycle assessment
- 11.610.1.1 Whole-building life cycle assessment
- 11.610.1.2 Life cycle assessment for a product or assembly
- 11.611 INNOVATIVE PRACTICES [Go to Page]
- 11.611.1 Manufacturer’s environmental management system concepts
- 11.611.2 Sustainable products
- 11.611.3 Universal design elements
- 11.611.4 Product declarations
- 11.701 MINIMUM ENERGY EFFICIENCY REQUIREMENTS [Go to Page]
- 11.701.4 Mandatory practices
- 11.701.4.0 Minimum energy efficiency requirements
- 11.701.4.1 HVAC systems
- 11.701.4.2 Duct systems
- 11.701.4.3 Insulation and air sealing
- 11.701.4.4 High-efficacy lighting
- 11.701.4.5 Boiler supply piping
- 11.701.4.6 Fenestration specifications
- 11.701.4.7 Replacement fenestration
- 11.901 POLLUTANT SOURCE CONTROL [Go to Page]
- 11.901.0 Intent
- 11.901.1 Space and water heating options
- 11.901.2 Solid fuel-burning appliances
- 11.901.3 Garages
- 11.901.4 Wood materials
- 11.901.5 Cabinets
- 11.901.6 Carpets
- 11.901.7 Floor materials
- 11.901.8 Wall coverings
- 11.901.9 Interior architectural coatings
- 11.901.10 Interior Adhesives and sealants
- 11.901.11 Insulation
- 11.901.12 Carbon monoxide (CO) alarms
- 11.901.13 Building entrance pollutants control
- 11.901.14 Non-smoking areas
- 11.901.15 Lead-safe work practices
- 11.902 POLLUTANT CONTROL [Go to Page]
- 11.902.0 Intent
- 11.902.1 Spot ventilation
- 11.902.2 Building ventilation systems
- 11.902.3 Radon control
- 11.902.4 HVAC system protection
- 11.902.5 Central vacuum systems
- 11.902.6 Living space contaminants
- 11.903 MOISTURE MANAGEMENT: VAPOR, RAINWATER, PLUMBING, HVAC [Go to Page]
- 11.903.0 Intent
- 11.903.1 Plumbing
- 11.903.2 Duct insulation
- 11.903.3 Relative humidity
- 11.904 INDOOR AIR QUALITY [Go to Page]
- 11.904.0 Intent
- 11.904.1 Indoor Air Quality (IAQ) during construction
- 11.904.2 Indoor Air Quality (IAQ) post completion
- 11.905 INNOVATIVE PRACTICES [Go to Page]
- 11.905.1 Humidity monitoring system
- 11.905.2 Kitchen exhaust
- 11.1001 HOMEOWNER’S MANUAL AND TRAINING GUIDELINES FOR ONE- AND TWO-FAMILY DWELLINGS
[Go to Page]
- 11.1001.0 Intent
- 11.1001.1 Homeowner’s manual
- 11.1001.2 Training of initial building owners
- 11.1002 CONSTRUCTION, OPERATION, AND MAINTENANCE MANUALS AND TRAINING FOR
MULTIFAMILY BUILDINGS [Go to Page]
- 11.1002.0 Intent
- 11.1002.1 Building construction manual
- 11.1002.2 Operations manual
- 11.1002.3 Maintenance manual
- 11.1002.4 Training of building owners
- 11.1003 PUBLIC EDUCATION [Go to Page]
- 11.1003.0 Intent
- 11.1003.1 Public Education
- 11.1005 INNOVATIVE PRACTICES
- CHAPTER 12 REMODELING OF FUNCTIONAL AREAS [Go to Page]
- 12.0 REMODELING OF FUNCTIONAL AREAS [Go to Page]
- 12.0 Intent
- 12.0.1 Applicability
- 12.1 GENERAL
- 12.1.601.2 Material usage
- 12.1.602.1.7.1 Moisture control measures
- 12.1.602.1.7.2 Moisture content
- 12.1.602.1.11 Tile backing materials
- 12.1(A) Product or material selection
- 12.1(A).601.7 Prefinished materials
- 12.1(A).603.2 Reused and salvaged materials
- 12.1(A).604.1 Recycled content
- 12.1(A).605.1 Construction waste management plan
- 12.1(A).606.1 Biobased products
- 12.1(A).606.2 Wood-based products
- 12.1(A).608.1 Resource-efficient materials
- 12.1(A).609.1 Regional materials
- 12.1(A).610.1 Life cycle assessment
- 12.1(A).610.1.1 Functional area life cycle assessment
- 12.1(A).610.1.2 Life cycle assessment for a product or assembly
- 12.1(A).611.1 Manufacturer’s environmental management system concepts
- 12.1(A).611.2 Sustainable products
- 12.1.605.0 Hazardous materials and waste
- 12.1.701.4.0 Minimum Energy Efficiency Requirements
- 12.1.701.4.1.1 HVAC system sizing
- 12.1.701.4.2.1 Duct air sealing
- 12.1.701.4.2.2 Ducts and plenums
- 12.1.701.4.2.3 Duct system sizing
- 12.1.701.4.3.1 Building thermal envelope air sealing
- 12.1.701.4.3.2 Air sealing and insulation
- 12.1.701.4.3.4 Fenestration air leakage
- 12.1.701.4.3.5 Recessed lighting
- 12.1.701.4.4 High-efficacy lighting
- 12.1.701.4.5 Boiler supply piping
- 12.1.701.4.6 Fenestration specifications
- 12.1.701.4.7 Replacement fenestration
- 12.1.703.6.2 Appliances
- 12.1.901.1.4 Gas-fired equipment
- 12.1.901.2.1 Solid fuel-burning appliances
- 12.1.901.3 Attached garages
- 12.1.901.4 Wood materials
- 12.1.901.5 Cabinets
- 12.1.901.6 Carpets
- 12.1.901.7 Floor materials
- 12.1.901.8 Interior wall coverings
- 12.1.901.9 Architectural coatings
- 12.1.901.10 Adhesives and sealants
- 12.1.901.11 Insulation
- 12.1.901.15 Lead-safe work practices
- 12.1.902.1.1 Spot ventilation
- 12.1.902.4 HVAC system protection
- 12.1.903.2 Duct insulation
- 12.2 KITCHEN REMODELS [Go to Page]
- 12.2.0 Applicability
- 12.2.607.1 Recycling and composting
- 12.2.607.2 Food waste disposers
- 12.3.801.4.1 Faucets
- 12.3 BATHROOM REMODELS [Go to Page]
- 12.3.0 Applicability
- 12.3.611.3 Universal design elements
- 12.3.801.3 Showerheads
- 12.3.801.4.1 Faucets
- 12.3.801.5 Water closets
- 12.4 BASEMENT REMODELS [Go to Page]
- 12.4.0 Applicability
- 12.4.1 Moisture inspection
- 12.4.2 Kitchen
- 12.4.3 Bathroom
- 12.4.902.3 Radon control
- 12.5 CONVERSION OF PREVIOUSLY UNCONDITIONED SPACE TO CONDITIONED SPACE [Go to Page]
- 12.5.0 Applicability
- 12.5.1 Moisture inspection
- 12.5.2 Kitchen
- 12.5.3 Bathroom
- 12.5.4 Knee walls
- 12.6 ADDITIONS [Go to Page]
- 12.6.0 Applicability
- 12.6.1 Kitchen
- 12.6.2 Bathroom
- 12.6.503.5 Landscape plan
- 12.6.602.1.1.1 Capillary break
- 12.6.602.1.3.1 Exterior drain tile
- 12.6.602.1.4.1 Crawlspace
- 12.6.602.1.8 Water-resistive barrier
- 12.6.602.1.9 Flashing
- 12.6.602.1.13 Ice barrier
- 12.6.602.1.14 Architectural features
- 12.6.602.4.1 Finished grade
- 12.6.902.3 Radon control
- CHAPTER 13 REFERENCED DOCUMENTS [Go to Page]
- 1301 GENERAL
- 1302 REFERENCED DOCUMENTS
- APPENDIX A DUCTED GARAGE EXHAUST FAN SIZING CRITERIA
- APPENDIX B WHOLE BUILDING VENTILATION SYSTEM SPECIFICATIONS
- APPENDIX C CLIMATE ZONES
- APPENDIX D EXAMPLES OF THIRD-PARTY PROGRAMS FOR INDOOR ENVIRONMENTAL QUALITY
- APPENDIX E ACCESSORY STRUCTURES
- INDEX [Go to Page]