ASTM C1091-99
Historical Standard: ASTM C1091-99 Standard Test Method for Hydrostatic Infiltration and Exfiltration Testing of Vitrified Clay Pipe Lines
SUPERSEDED (see Active link, below)
ASTM C1091
1. Scope
1.1 This test method defines procedures for hydrostatically testing vitrified clay pipe lines, to demonstrate the structural integrity of the installed line.
1.2 This test method is suitable for testing gravity-flow pipe lines constructed of vitrified clay pipe or combinations of clay pipe and other pipe materials.
1.3 This test method is applicable to the testing of the pipe lines only. Manholes or other structures should be tested separately.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C12 Practice for Installing Vitrified Clay Pipe Lines
C828 Test Method for Low-Pressure Air Test of Vitrified Clay Pipe Lines
C896 Terminology Relating to Clay Products
Keywords
air test; clay pipe; hydrostatic test; infiltration; pipe; pressure test; sewers; vitrified clay pipe; water test; Acceptance criteria/testing--clay pipe/fittings; Clay pipe/piping systems; Exfiltration rate; Field testing; Hydrostatic testing; Infiltration rate; Pressure testing--clay pipe; Pressure testing--pipes; Sewerlines; Standpipes; Vitrified clay pipe/fittings; Water analysis; Water supply/distribution systems; Water test
ICS Code
ICS Number Code 91.100.25 (Terracotta building products)