ASTM C1127-95
Historical Standard: ASTM C1127-95 Standard Guide for Use of High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane with an Integral Wearing Surface
SUPERSEDED (see Active link, below)
ASTM C1127
1. Scope
1.1 This guide describes the design and installation of cold liquid-applied elastomeric waterproofing membrane systems that have an integral wearing surface. The cold liquid-applied elastomeric waterproofing membrane (membrane) to which this guide refers is specified in Specification C957.
1.2 Concrete Slab-on-Grade --Waterproofing the upper surface of a concrete slab on grade presents special problems due to the possibility of negative hydrostatic pressure causing loss of bond to the substrate. Consideration of these problems is beyond the scope of this guide. Consult the membrane manufacturer for recommendations when this situation exists.
1.3 The committee having jurisdiction for this guide is not aware of any similar ISO standard.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Note in 15.4.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
C330 Specification for Lightweight Aggregates for Structural Concrete
C332 Specification for Lightweight Aggregates for Insulating Concrete
C717 Terminology of Building Seals and Sealants
C755 Practice for Selection of Water Vapor Retarders for Thermal Insulation
C920 Specification for Elastomeric Joint Sealants
C957 Specification for High-Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane With Integral Wearing Surface
C962 Standards Guide for Use of Elastomeric Joint Sealants
C1193 Guide for Use of Joint Sealants
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D1752 Specification for Preformed Sponge Rubber Cork and Recycled PVC Expansion Joint Fillers for Concrete Paving and Structural Construction
D2628 Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
American Concrete Institute (ACI) Standard
301-84 (1985) Specification for Structural Concrete for Buildings Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.concrete.org.U.S. Department of Commerce Standard
Product Standard PS Construction and Industrial Plywood Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http://www.nist.gov.Steel Structures Painting Council (SSPC) Standards
Specification SSPC S Commercial Blast CleaningAmerican Plywood Association (APA) Standard
APA Plywood Construction Guide Available from American Plywood Assoc. (Forest Industries), P.O. Box 11700, Tacoma, WA 98411.Keywords
design; installation; membrane; waterproofing; Substrates; Surface preparation; Building design and construction; Decks; Elastomeric seals/sealants; Elastomeric waterproofing membranes; Installation--building materials/applications; Integral wearing surfaces; Plazas; Plywood; Roofing membranes; Solid phase materials; Structural concrete; Structural roof decks;
ICS Code
ICS Number Code 83.140.99 (Other rubber and plastic products)
DOI: 10.1520/C1127-95