ASTM D4492-07
Historical Standard: ASTM D4492-07 Standard Test Method for Analysis of Benzene by Gas Chromatography
SUPERSEDED (see Active link, below)
ASTM D4492
1. Scope
1.1 This test method covers the determination of normally occurring trace impurities in, and the purity of, finished benzene by gas chromatography.
1.2 This test method is applicable for benzene purities of 99.80 weight % or higher.
1.3 The lower limit of detection for total non-aromatic impurities is 0.005 weight %. The lower limit of detection for individual aromatic hydrocarbon impurities in 0.001 weight %. The lower limit of detection for 1,4-dioxane is 0.0005 weight %.
1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding off method of Practice E 29.
1.5 &solely-SI-units;
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D852 Test Method for Solidification Point of Benzene
D3437 Practice for Sampling and Handling Liquid Cyclic Products
D6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
E260 Practice for Packed Column Gas Chromatography
E355 Practice for Gas Chromatography Terms and Relationships
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E1510 Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
Other Document
OSHARegulations,29CF paragraphs 1910.1000 and 1910.1200 Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://www.access.gpo.gov.Keywords
benzene; gas chromatography; purity; Impurities--organic compounds; Nonaromatic impurities; Purity analysis--paints/related coatings/materials; Trace elements--paints/related coatings/materials; Benzene--paints/related coatings/materials; Gas chromatography (GC)--paints/related coatings/materials ;
ICS Code
ICS Number Code 71.080.15 (Aromatic hydrocarbons)
DOI: 10.1520/D4492-07
ASTM International is a member of CrossRef.