EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E1331 2009ASTM E1331 - 09Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Hemispherical GeometryActive Standard ASTM E1331 | Developed by Subcommittee: E12.02 Book of Standards Volume: 06.01 ASTM E1331Significance and Use The most direct and accessible methods for obtaining the color coordinates of object colors are by instrumental measurement using spectrophotometers or colorimeters with either hemispherical or bidirectional optical measuring systems. This test method provides procedures for such measurement by reflectance spectrophotometry using a hemispherical optical measuring system. This test method is especially suitable for measurement of the following types of specimens for the indicated uses (Guide E179 and Practice E805 ): All types of object-color specimens to obtain data for use in computer colorant formulation. Object-color specimens for color assessment. For the measurement of plane-surface high-gloss specimens, the specular component should generally be excluded during the measurement. For the measurement of plane-surface intermediate-gloss specimens and of textured-surface specimens, including textiles, where the first-surface reflection component may be distributed over a wide range of angles, measurement may be made with the specular component included, but the resulting color coordinates may not correlate best with visual judgments of the color. The use of bidirectional geometry, such as 45/0 or 0/45, may lead to better correlations. For the measurement of plane-surface, low-gloss (matte) specimens, the specular component may either be excluded or included, as no significant difference in the results should be apparent. Specimens with bare metal surfaces for color assessment. For this application, the specular component should generally be included during the measurement. This test method is not recommended for measurement of the following types of specimens, for which the use of bidirectional measurement geometry (0/45 or 45/0) is preferable (Guide E179 ): Object-color specimens of intermediate gloss, Retroreflective specimens, and Fluorescent specimens (Practice E991 ). When there is doubt as to whether the specular component of reflection should be included or excluded, both measurements should be made, and the results correlated with visual judgments. Thereafter, the method with higher visual correlation should be utilized. When measurements of two specimens whose gloss, or texture, are substantially different from each other, are to be utilized in a color-difference comparison, generally the specular component should be included in each measurement. This has the effect of including in both measurements all the first surface reflections whether diffuse or specular. These first surface reflections are subtracted from each other in the color-difference equation, and differences in the body color remain, which is what is usually sought. 1. Scope 1.1 This test method describes the instrumental measurement of the reflection properties and color of object-color specimens by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most object-color specimens. However, it should not be used for retroreflective specimens or for fluorescent specimens when highest accuracy is desired. Specimens having intermediate-gloss surfaces should preferably not be measured by use of this geometry. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates E179 Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials E284 Terminology of Appearance E308 Practice for Computing the Colors of Objects by Using the CIE System E805 Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials E991 Practice for Color Measurement of Fluorescent Specimens Using the One-Monochromator Method E1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation E1345 Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple Measurements Keywords color; hemispherical geometry; reflectance; reflectance factor; spectrophotometry; Color--opaque materials; Colorimetric analysis; Geometric analysis--paints/related coatings/materials; Hemispherical geometry; Instrumental measurement--color/light; Reflectance and reflectivity--paints/related coatings/materials; Spectrophotometry ; ICS Code ICS Number Code 17.180.20 (Colours and measurement of light) DOI: 10.1520/E1331-09 ASTM International is a member of CrossRef. ASTM E1331The following editions for this book are also available...
This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |