ASTM E2126-08
Historical Standard: ASTM E2126-08 Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings
SUPERSEDED (see Active link, below)
ASTM E2126
1. Scope
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D2395 Test Methods for Specific Gravity of Wood and Wood-Based Materials
D4442 Test Methods for Direct Moisture Content Measurement of Wood and Wood-Base Materials
D4444 Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters
E564 Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings
E575 Practice for Reporting Data from Structural Tests of Building Constructions, Elements, Connections, and Assemblies
E631 Terminology of Building Constructions
ISO Standard
ISO 16670 Timber Structures--Joints Made with Mechanical Fasteners--Quasi-static Reversed-cyclic Test MethodOther Standards
ANSI/AF&PA NDS National Design Specification for Wood ConstructionKeywords
cyclic loads; earthquake; framed walls; lateral-force resisting systems; portal frames; racking loads; rigid support; shear displacement; shear stiffness; shear strength; structural insulated panels;: Cyclic (reversed) load test; Framed building constructions; Loading tests--building constructions/materials; Reversed cyclic testing; Shear testing--building materials; Walls ;
ICS Code
ICS Number Code 91.060.10 (Walls. Partitions. Facades)
DOI: 10.1520/E2126-08
ASTM International is a member of CrossRef.









