ASTM E2153-01
Historical Standard: ASTM E2153-01 Standard Practice for Obtaining Bispectral Photometric Data for Evaluation of Fluorescent Color
SUPERSEDED (see Active link, below)
ASTM E2153
1. Scope
1.1 This practice addresses the instrumental measurement requirements, calibration procedures, and material standards needed for obtaining precise bispectral photometric data for computing the colors of fluorescent specimens.
1.2 This practice lists the parameters that must be specified when bispectral photometric measurements are required in specific methods, practices, or specifications.
1.3 This practice applies specifically to bispectrometers, which produce photometrically quantitative bispectral data as output, useful for the characterization of appearance, as opposed to spectrofluorimeters, which produce instrument-dependent bispectral photometric data as output, useful for the purpose of chemical analysis.
1.4 The scope of this practice is limited to the discussion of object-color measurement under reflection geometries; it does not include provisions for the analogous characterization of specimens under transmission geometries.
1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E179 Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials
E284 Terminology of Appearance
E925 Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidth does not Exceed 2 nm
E958 Practice for Measuring Practical Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers
E1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation
E1341 Practice for Obtaining Spectroradiometric Data from Radiant Sources for Colorimetry
E2152 Practice for Computing the Colors of Fluorescent Objects from Bispectral Photometric Data
NPL Publications
NPLReportMOM12 Problems of spectrofluorimetric standards for reflection and colorimetric use Available from National Physical Laboratory, Queens Road, Teddington, Middlesex, United Kingdom TW11 0LW, http://www.npl.co.uk/.CIE Publications
CIEReportofTC-2.25: Calibration Methods and Photoluminescent Standards for Total Radiance Factor MeasurementNIST Publications
NBSNo.260-66 Didymium Glass Filters for Calibrating the Wavelength Scale of Spectrophotometers Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http://www.nist.gov.Keywords
bispectral; bispectrometer; calibration; color; colorimetry; Donaldson matrix; Donaldson radiance factor; fluorescence; instrumental measurement; luminescence; radiance factor; spectrophotometry;
ICS Code
ICS Number Code 35.240.99 (IT applications in other fields)
DOI: 10.1520/E2153-01