ASTM F1867-06
Historical Standard: ASTM F1867-06 Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation
SUPERSEDED (see Active link, below)
ASTM F1867
1. Scope
1.1 This practice covers the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, and process piping.
1.2 This practice is to be used with the material specified in Section of Specification F 1871.
1.3 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 There is no similar or equivalent ISO Standard.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D638 Test Method for Tensile Properties of Plastics
D648 Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
F1417 Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure Air
F1871 Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
Uni-Bell Standard
UNI-B-5-89 Recommended Practice for the Installation of Polyvinyl Chloride (PVC) Sewer Pipe Available from Uni-Bell PVC Pipe Association, 2711 LBJ Freeway, Suite 1000, Dallas, TX 75234, http://www.uni-bell.org.Keywords
plastic pipe, thermoplastic; poly(vinyl chloride)(PVC) plastic pipe; rehabilitation, trenchless technology; Conduits; Folded PVC pipe; Installation--plastic pipe materials/applications; Poly(vinyl chloride)(PVC) pipe; Sewer pipe (thermoplastic)
ICS Code
ICS Number Code 23.040.20 (Plastic pipes); 83.080.20 (Thermoplastic materials)
DOI: 10.1520/F1867-06