Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
EDITION
to
PUBLISHER
(1)
(353)
(628)
(599)
(58)
(290)
(1020)
(712)
(2227)
(117)
(95826)
(63)
(601)
(131)
(33)
(26)
(20)
(96970)
(17)
(1)
(396)
(325)
(7369)
(252)
(21)
(7)
(1685)
(18)
(19)
(28)
(4)
 
(6)
(7)
(117)
(1)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(28)
(27)
(34)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS 7288:2016 Specification for residual current devices with or without overcurrent protection for socket-outlets for household and similar uses
    Edition: 2016
    $631.50
    / user per year

Description of BS 7288:2016 2016

This British Standard applies to residual current-operated devices (RCD) incorporated in, or specifically intended for use with, single pole and neutral and single pole and switched neutral and double pole socket-outlets, with provision of earthing of the socket-outlet for household and similar uses (SRCD: socket-outlet residual current devices). SRCDs, according to this standard, are intended to be used in single phase systems such as phase to neutral. SRCDs are only intended to provide supplementary protection downstream of the SRCD. SRCDs are intended for use in circuits where the fault protection and additional protection are already assured upstream of the SRCD.

NOTE 1 Void

NOTE 2 Void

NOTE 3 Void

SRCDs are neither intended to provide an isolation function nor intended to be used in IT systems.

NOTE 4 For SRCDs intended to provide isolation or fault protection, or to be used in IT systems, BS EN 61008-1 or BS EN 61009-1 should be used, as applicable, in conjunction with the requirements of BS 1363-2 for socket-outlets.

NOTE 5 Requirements and testing for SRCDs intended to be used in IT systems are under consideration.

SRCDs are not used in distribution boards. They are not intended for the protection of a complete distribution circuit or a complete final circuit. These products are intended to be installed:

  • in boxes in compliance with BS EN 60670-1; or

  • in cable trunking systems in compliance with the BS EN 61084 series; or

  • in power track systems in compliance with the BS EN 61534 series; or

  • in boxes according to one of the above standards adjacent to socket-outlet boxes.

They are not intended to be used in enclosures or distribution boards in conformity with BS EN 60670-24, BS EN 61439-1 or BS EN 61439-3.

RCDs for household and similar use not covered by the scope of this standard are covered by BS EN 61008-1 or BS EN 61009-1. SRCDs energized from batteries, or a circuit other than the one powering the loads, are not covered by this standard.

The residual current device incorporates the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening the protected circuit when the residual current exceeds this value.

The maximum rated residual operating current is 30 mA.

The maximum rated current is 16 A for devices with a rated voltage not exceeding 250 V a.c.

NOTE 6 Void

NOTE 7 Void

This British Standard applies to SRCDs incorporating overload or overcurrent protection.

This standard also applies to a connection unit incorporating a residual current device intended to protect fixed electrical equipment.

NOTE 8 SRCDs are designed to be operated by uninstructed persons and not to require maintenance.

The requirements of this standard apply for normal conditions of temperature and environment. Additional requirements may be necessary for devices used in locations having more severe environmental conditions.

The socket-outlet part of an SRCD is covered by BS 1363-2. The connection unit part of an SRCD is covered by BS 1363-4.





The following editions for this book are also available...