|
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content DescriptionThis document specifies a method for the determination of the receiving sensitivity spectra of a piezoelectric acoustic emission sensor, in absolute units of volts output per motion input, whereby the motion can be particle displacement (e.g. in nanometres) or particle velocity (e.g. in millimetres per second) over a frequency range used for acoustic emission testing, from 20 kHz to about 1,5 MHz, whereby the sensor is stimulated by a motion pulse in normal direction to the sensor’s face from a directly coupled piezoelectric transmitter. This document also specifies a method for the determination of the transmitting sensitivity spectrum of a piezoelectric transmitter in absolute units, for example, in nanometres output per volt input, by measuring both the particle displacement pulse over the transmitter’s active face and the transmitter’s input voltage spectrum, using a scanning laser vibrometer. This document does not include the known cancellation effects on a sensor’s response, when the angle of incidence differs from normal (90°) or when the length of the wave passing across the sensor’s sensitive face is shorter than about 10 times the dimension of the sensor’s sensitive face. This document does not specify a method to measure the influence of different materials on a sensor’s sensitivity, but this effect is addressed in Annex F. NOTE The methods described in this document can be considered for use with other than piezoelectric sensors, which detect motion at a flat face and work in the same frequency range. About ISOISO, the International Organization for Standardization, brings global experts together to agree on the best way of doing things – for anything from making a product to managing a process. As one of the oldest non-governmental international organizations, ISO has enabled trade and cooperation between people and companies all over the world since 1946. The International Standards published by ISO serve to make lives easier, safer and better. |
GROUPS
|